Code: 121.26...121.31
Description: 121.25 After line voltage detection, control did not roll over to steady state control in time 121.26 Fuser failed to reach temperature during warm up 121.28 Fuser failed to reach EP warm-up temperature in time 121.29 Fuser failed to reach preheat temperature for motor start during warm up 121.30 Fuser failed to reach printing temperature by the time a page got to the fuser 121.31 Fuser has gotten too hot
Remedy: Step 1 Ensure the cable for socket “J24” on the controller board is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connections. Go to step 2.
Step 2 Reset the machine. Does the error continue? Replace the fuser drive motor. See “Fuser drive motor removal”. Go to step 3. Problem resolved
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
Step 2 Reset the machine. Does the error continue? Replace the fuser drive motor. See “Fuser drive motor removal”. Go to step 3. Problem resolved
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.