Code: 120.10...120.80
Description: 120.10 Fuser drive Motor Halls detection error 120.20 Fuser drive Motor took too long to stop 120.30 Fuser drive Motor Unable To Lock (before motor ID) 120.40 Fuser drive motor over.speed error 120.60 Fuser drive motor unable to lock (after motor ID) 120.70 Fuser drive motor out of lock 120.80 Fuser drive motor excessive PWM / over temperature
Remedy: Step 1 Ensure the cable for socket “J24” on the controller board is properly connected. Is the above connection properly connected? Go to step 2. Reseat the connections. Go to step 2.
Step 2 Reset the machine. Does the error continue? Replace the fuser drive motor. See “Fuser drive motor removal”. Go to step 3. Problem resolved
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.
Step 2 Reset the machine. Does the error continue? Replace the fuser drive motor. See “Fuser drive motor removal”. Go to step 3. Problem resolved
Step 3 Reset the machine. Does the error continue? Replace the controller board. See “Controller board removal”. Problem resolved.