Description: Scanner - ASIC communication error A communication error is detected during communication. (Read-back values are different.)
Remedy: CIS 1. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. CIS - Main/Engine PWB (YC506) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. Replace the image scanner carriage and execute U411. Main/Engine PWB Replace the main/engine PWB.