Code: 1010
Description: Lift motor error (50/60 ppm model only)
After cassette 1 is inserted, lift sensor does not turn on within 10 s. This error is detected four times successively.
After cassette 1 is inserted, lift sensor does not turn on within 10 s. This error is detected four times successively.
Causes: Bottom plate elevation mechanism in the cassette. Connector cable or poor contact in the connector. Drive transmission system of the lift motor. Lift motor. Connect right PWB. Control PWB.
Remedy: Bottom plate elevation mechanism in the cassette Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and connect right PWB (YC9) Connect right PWB and control PWB (YC29)
Drive transmission system of the lift motor Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Lift motor Replace the lift motor.
Connect right PWB Replace the connect right PWB.
Control PWB Replace the control PWB and check for correct operation.
Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and connect right PWB (YC9) Connect right PWB and control PWB (YC29)
Drive transmission system of the lift motor Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
Lift motor Replace the lift motor.
Connect right PWB Replace the connect right PWB.
Control PWB Replace the control PWB and check for correct operation.