Code: 2000
Description: Main motor startup error
Main motor is not stabilized within 2 s since the motor is activated.
Main motor is not stabilized within 2 s since the motor is activated.
Causes: Main motor. Connect right PWB. Control PWB
Remedy: Main motor 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Main motor and connect right PWB (YC10) Connect right PWB and control PWB (YC29) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the main motor.
Connect right PWB Replace the cconnect right PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation.
Connect right PWB Replace the cconnect right PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation.