Code: 2620
Description: PF drive motor 3 error (paper feeder 3)
When the PF drive motor is driven, error signal is detected continuously for 2 s.
When the PF drive motor is driven, error signal is detected continuously for 2 s.
Causes: Connector cable or poor contact in the connector. Drive transmission system of the PF drive motor. PF drive motor. PF main PWB.
Remedy: Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF drive motor 3 and PF main PWB (YC6)
Drive transmission system of the PF drive motor Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
PF drive motor Replace the PF drive motor 3.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
Drive transmission system of the PF drive motor Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
PF drive motor Replace the PF drive motor 3.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).