Code: 3200
Description: Exposure lamp error
When a lamp is made to turn on one side at a time, the white standard data at the time of an initial is lower than a rated value.
When a lamp is made to turn on one side at a time, the white standard data at the time of an initial is lower than a rated value.
Causes: LED PWB. CCD PWB. Control PWB.
Remedy: LED PWB 1. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. LED PWB and CCD PWB (YC2) CCD PWB and control PWB (YC1000) 2. Replace the image scanner unit.
CCD PWB Replace the image scanner unit and execute U411.
Control PWB Replace the control PWB and check for correct operation.
CCD PWB Replace the image scanner unit and execute U411.
Control PWB Replace the control PWB and check for correct operation.