Mã lỗi 6020 — Kyocera ECOSYS M3040dn

Code: 6020

Description: Abnormally high fuser thermistor 2 temperature (Center)
(50/60 ppm model only) Fuser thermistor 2 detects a temperature higher than 235°C/455°F. In a heater-off state, the detection temperature of fuser thermistor 2 is higher than 195°C/383°F after the detection temperature of fuser thermistor 2 was 155°C/311°F or less.
Causes: Fuser unit. Fuser thermistor connect PWB. Control PWB.
Remedy: Fuser unit 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and fuser thermistor connect PWB (YC2) Fuser thermistor connect PWB and control PWB (YC21) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit.
Fuser thermistor connect PWB Replace the fuser thermistor connect PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation.

← Xem tất cả mã lỗi Kyocera ECOSYS M3040dn