Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 6030 — Kyocera ECOSYS M3040dn

Code: 6030

Description: Broken fuser thermistor 2 wire (Center)
(50/60 ppm model only) Input from fuser thermistor 2 is 1019 or more (A/D value) continuously for 4 s.
Causes: Fuser unit. Fuser thermistor connect PWB. Control PWB. Fuser thermistor 2. Fuser thermostat (triggered). Power source PWB
Remedy: Fuser unit 1. Check that no paper jam is present. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and fuser thermistor connect PWB (YC2) Fuser thermistor connect PWB and control PWB (YC21) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the Fuser unit. (Deteriorated sensitivity due to the toner adhered to the center thermistor.)
Fuser thermistor connect PWB Replace the fuser thermistor connect PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB.
Fuser thermistor 2 1. Replace the Fuser unit.
Fuser thermostat (triggered) 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Fuser unit and power source PWB (YC2) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the Fuser unit.
Power source PWB Replace the power source PWB.

← Xem tất cả mã lỗi Kyocera ECOSYS M3040dn