Mã lỗi 6120 — Kyocera ECOSYS M3040dn

Code: 6120

Description: Abnormally high fuser thermistor 1 temperature
(50/60 ppm model) The detection temperature of fuser thermistor 1 is higher than 245°C/473°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 195°C/383°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less. (40 ppm model) The detection temperature of fuser thermistor 1 is higher than 250°C/482°F. In a heater-off state, the detection temperature of fuser thermistor 1 is higher than 170°C/338°F after the detection temperature of fuser thermistor 1 was 155°C/311°F or less.
Causes: Connector pin. Triac. Fuser thermistor. Contrl PWB.
Remedy: Fuser thermistor Replace the fuser unit.
Contrl PWB Replace the control PWB and check for correct operation.