Code: 6130
Description: Broken fuser thermistor 1 wire (50/60 ppm model only)
A/D value of the fuser thermistor 1 exceeds 1019 bit continuously for 4 s during warming up.
A/D value of the fuser thermistor 1 exceeds 1019 bit continuously for 4 s during warming up.
Causes: Connector cable or poor contact in the connector. Connector pin. Triac. Fuser thermistor. Fuser thermistor connect PWB. Control PWB.
Remedy: Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser thermistor and fuser thermistor connect PWB (YC1) Fuser thermistor connect PWB and control PWB (YC21)
Fuser thermistor Replace the fuser unit.
Fuser thermistor connect PWB Replace the fuser thermistor connect PWB.
Control PWB Replace the control PWB and check for correct operation.
Fuser thermistor Replace the fuser unit.
Fuser thermistor connect PWB Replace the fuser thermistor connect PWB.
Control PWB Replace the control PWB and check for correct operation.