Code: 7000
Description: Toner motor error
During driving the toner motor, an over-current detection signal is detected at intervals of 10 ms as for 300 accumulation.
During driving the toner motor, an over-current detection signal is detected at intervals of 10 ms as for 300 accumulation.
Causes: Connector cable or poor contact in the connector. Drum unit. Connect left PWB. Control PWB.
Remedy: Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Toner motor and drum PWB (YC4) Drum PWB and drum connect PWB (YC1) Drum connect PWB and connect left PWB (YC3) Connect left PWB and control PWB (YC3)
Drum unit Replace the drum unit.
Connect left PWB Replace the connect left PWB.
Control PWB Replace the control PWB and check for correct operation.
Drum unit Replace the drum unit.
Connect left PWB Replace the connect left PWB.
Control PWB Replace the control PWB and check for correct operation.