Code: 7410
Description: Drum unit type mismatch error
The drum PWB EEPROM does not communicate normally. Absence of the drum unit is detected.
The drum PWB EEPROM does not communicate normally. Absence of the drum unit is detected.
Causes: Connector cable or poor contact in the connector. Toner sensor. Connect left PWB. Control PWB.
Remedy: Connector cable or poor contact in the connector Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit and drum connect PWB (YC1) Drum connect PWB and connect left PWB (YC3) Connect left PWB and control PWB (YC2)
Toner sensor Replace the drum unit.
Connect left PWB Replace the connect left PWB.
Control PWB Replace the control PWB and check for correct operation.
Toner sensor Replace the drum unit.
Connect left PWB Replace the connect left PWB.
Control PWB Replace the control PWB and check for correct operation.