Code: 7810
Description: Short-circuited temperature sensor wire
Input from temperature sensor is 31 or less continuously for 5 s.
Input from temperature sensor is 31 or less continuously for 5 s.
Causes: Temperature sensor. Control PWB.
Remedy: Temperature sensor 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Temperature sensor and control PWB (YC30) 2. If the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the key right PWB.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation.
Control PWB 1. Check the control software and upgrade to the latest, if necessary. 2. Replace the control PWB and check for correct operation.