Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 1510 — Kyocera ECOSYS M6026cdn

Code: 1510

Description: PF heater 2 high temperature error (paper feeder 1)
A temperature higher than 75C/167F is detected.
Causes: Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 2 and PF main PWB (YC111)
Shorted PF thermistor 2. Replace the side heater unit (Refer to the service manual for the paper feeder).
Defective PF fan motor 2. Replace the side heater unit (Refer to the service manual for the paper feeder).
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).