Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 1520 — Kyocera ECOSYS M6026cdn

Code: 1520

Description: PF heater 1 high temperature error (paper feeder 2)
A temperature higher than 75aC/167F is detected.
Causes: Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 1 and PF main PWB (YC111)
Shorted PF thermistor 1. Replace the top heater unit (Refer to the service manual for the paper feeder).
Defective PF fan motor 1. Replace the top heater unit (Refer to the service manual for the paper feeder).
Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).

← Xem tất cả mã lỗi Kyocera ECOSYS M6026cdn

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie