Code: 3200
Description: Exposure lamp error
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s.
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s.
Causes: Defective connector cable or poor contact in the connector. Defective exposure lamp. Defective inverter PWB or CCD PWB. Defective main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Exposure lamp and inverter PWB (CN2) Inverter PWB (CN1) and CCD PWB (YC3) CCD PWB (YC1) and main PWB (YC8)
Defective exposure lamp. Replace the scanner unit.
Defective inverter PWB or CCD PWB. Replace the scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.
Defective exposure lamp. Replace the scanner unit.
Defective inverter PWB or CCD PWB. Replace the scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.