Code: 4201
Description: Laser output error (black)
The pin photo signal is not output from PD PWB K for one second while laser is emitted.
The pin photo signal is not output from PD PWB K for one second while laser is emitted.
Causes: Defective connector cable or poor contact in the connector. Defective APC PWB K. Defective PD PWB K. Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. APC PWB K and engine PWB (YC31)
Defective APC PWB K. Replace the laser scanner unit KM.
Defective PD PWB K. Replace the laser scanner unit KM.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Defective APC PWB K. Replace the laser scanner unit KM.
Defective PD PWB K. Replace the laser scanner unit KM.
Defective engine PWB. Replace the engine PWB and check for correct operation.