Code: 4002
Description: Polygon motor MC error The polygon motor MC ready input is not given for 10 seconds during the polygon motor MC is ON.
Remedy: Defective harness between polygon motor MC and engine PWB (YC30), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective laser scanner unit MC. Replace the laser scanner unit MC.
Defective engine PWB. Replace the engine PWB.
Defective laser scanner unit MC. Replace the laser scanner unit MC.
Defective engine PWB. Replace the engine PWB.