Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 4600 — Kyocera ECOSYS P6030cdn

Code: 4600

Description: LSU cleaning motor error When the LSU cleaning motor is driven, the LSU cleaning motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals.
Remedy: Defective harness between LSU cleaning motor and engine PWB (YC37), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective drive transmission system of the LSU cleaning motor. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective LSU cleaning motor. Replace the LSU cleaning motor.
Defective engine PWB. Replace the engine PWB.

← Xem tất cả mã lỗi Kyocera ECOSYS P6030cdn