Mã lỗi 1020 — Kyocera ECOSYS P7040cdn

Code: 1020

Description: PF lift motor error (PF1) The following states have been detected 5 times in succession. The lift motor overcurrent is detected for 200 ms. After the cassette is installed, the upper limit detection sensor does not turn ON within 10 s. During printing, after the upper limit detection sensor detects off, and 1 s after ascending control, and the upper limit detection sensor does not detect on. The upper limit detection sensor does not turn off within 5 s after descending control. The upper limit detection sensor does not turn on within 5 s after ascending control.
Remedy: Bottom plate Check to see if the bottom plate can move smoothly and repair or replace it if any problem is found.
Defective connector cable or poor contact in the connector 1. Reconnect the connector if its connection is loose. 2. If a wire is pinched by other component, or has defect conduction, replace it. PF lift motor 1 and PF main PWB (YC7) LPF1 main PWB and Engine relay PWB (YC19)
Drive transmission system for the lift motor 1. Check if the gears rotate smoothly. If not, clean or grease the bushes and gears. 2. Check broken gears and replace if any.
PF lift motor 1 Replace the PF lift motor 1.
PF1 main PWB PF lift sensor (upper limit detection sensor) 1. Check if the actuator of the PF lift sensor can be turned ON/OFF to suit the rise of the cassette bottom plate. 2. Replace the PF1 main PWB..
Engine relay PWB Replace the engine relay PWB.