Mã lỗi C0350 — Kyocera ECOSYS P8060cdn

Code: C0350

Description: Panel PWB communication error (Electronic volume I2C communication error) Since NACK was received during the I2C communication, the retry was repeated 5 times and the initial command was transmitted, and then the retry was repeated 5 times again. After that, NACK was also received.
Remedy: 1 Resetting the main power The operation of the operation panel main PWB is faulty. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . Operation panel main PWB - Main PWB Section 8 "PWBs" 3 Replacing the operation panel main PWB The operation panel main PWB is faulty. Replace the panel main PWB. Detaching and reattaching the Operation Panel Main PWB 4 Replacing the main PWB The main PWB is faulty. Replace the main PWB. Detaching and reattaching the Main PWB