Code: C1000
Description: MP lift motor error 1. When the MP lift motor rotates in the descending direction, the MP position sensor does not turn on within 1850ms. 2. When the MP lift motor rotates in the ascending direction, the MP position sensor does not turn off within 1600ms.
Remedy: 1 Checking the MP lift plate The MP lift plate does not operate properly. Repair or replace the MP lift plate on the MP tray when it does not move vertically. 2 Checking the lift lever The lift lever is not properly attached. Check if the lift lever is vertically shifted by the lift motor cam, or if it has the excessive load. Then, reattach the MP tray. Then, replace the MP tray if it is not fixed. 3 Checking the drive gear The drive gear to lift up the MP lift plate does not rotate properly. Check if the MP lift plate lift-up drive gears rotate smoothly or have no excessive load. And apply the grease (EM-50LP, Part no.: 7BG010009H) to the sliding section and repair the related parts so that they can rotate smoothly. 4 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . Main unit - Paper conveying unit . MP position sensor - Relay connector - Feed drive PWB . Feed drive PWB - Engine PWB Section 8 "PWBs" 5 Replacing the MP lift motor The MP lift motor does not operate properly. Replace the MP lift motor. 6 Checking the MP position sensor The MP position sensor is not attached properly. Reattach MP position sensor. 7 Replacing the MP position sensor The MP position sensor is faulty. Replace MP position sensor. 8 Replacing the feed drive PWB The feed drive PWB is faulty. Replace the feed drive PWB. 9 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update 10 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB