Code: C1140
Description: PF lift motor error (Side deck) Object: Side deck 1. The PF lift upper limit sensor does not turn on even 30s passed after inserting the cassette5. 2. The lock signal is detected for 200ms continuously during the operation of PF lift motor. 3. When start printing, PF lift upper limit sensor does not detect on even passing 2s from ascending control.
Remedy: 1 Checking the PF lift plate The PF lift plate does not operate properly. Repair or replace the PF lift plate when it does not move vertically. 2 Checking the drive gear The drive gear to lift up the PF lift plate does not rotate properly. Check if the PF lift plate lift-up drive gears rotate smoothly or have no excessive load. And apply the grease (EM-50LP, Part no.: 7BG010009H) to the sliding section and repair the related parts so that they can rotate smoothly. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . PF lift motor - PF PWB Section 8 "PWBs" 4 Checking the PF lift motor The PF lift motor is faulty. Replace the PF lift motor. 5 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . PF lift upper limit sensor - PF PWB Section 8 "PWBs" 6 Checking the PF lift upper limit sensor The PF lift upper limit sensor is not properly attached, or it is faulty. Reattach the PF lift upper limit sensor. Then, replace it if it is not fixed. 7 Checking the PF PWB The PF PWB is faulty. Replace the PF PWB. Detaching and reattaching the PF PWB