Description: Primary transfer unit EEPROM error 1. Five times consecutive detection of no response from the device for more than 5ms on reading / writing. 2. Data read in 2 places does not match 8 consecutive times. 3. Writing data and reading data does not match 8 consecutive times.
Remedy: 1 Reinstalling the primary transfer unit The primary transfer unit is not properly installed. Reinstall the primary transfer unit. Detaching and reattaching the Primary Transfer Unit 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . Primary transfer unit - Transfer PWB . Transfer PWB - Feed image PWB . Feed image PWB - Engine PWB Section 8 "PWBs" 3 Primary transfer unit replacement The primary transfer unit is faulty. Replace the primary transfer unit. Detaching and reattaching the Primary Transfer Unit 4 Replacing the feed image PWB The feed image PWB is faulty. Replace the feed image PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB