Code: C5104
Description: Main high-voltage error Y When measuring the inflow electric current changing Vpp to 3 steps during the Vpp adjustment, the gap between the 0 electric current value and the 2nd electric current value is the standard value or less.
Remedy: 1 Reinstalling the main highvoltage PWB Proper current does not flow as the MC roller contact point of the main high voltage PWB is not properly contacted. Reinstall the main high-voltage PWB. Detaching and reattaching the Main High Voltage PWB 2 Checking the drum unit and the developer unit The drum or the drum screw is not rotated properly due to the excessive load. Check if the drum or the drum screw is rotated manually, and replace the drum unit if not rotated. Detaching and reattaching the Drum Unit 3 Checking drum motor CMY Drum motor CMY does not rotate properly due to the excessive load. Replace drum motor CMY. 4 Checking the main charger unit Proper current does not flow as the foreign objects, etc. adheres to the high voltage contact point of the main charger unit. Clean the high-voltage contact of the main charger unit, and apply conductive grease to the roller shaft. Detaching and reattaching the Main Charger Unit 5 Main charger unit replacement Proper current does not flow as the high voltage contact point of the main charger unit is deformed or damaged. Replace the main charger unit and execute U930. Detaching and reattaching the Main Charger Unit Maintenanc e Mode List 6 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . Main high voltage PWB - Engine PWB Section 8 "PWBs" 7 Replacing the main highvoltage PWB The main high-voltage PWB is faulty. Replace the main high-voltage PWB. Detaching and reattaching the Main High Voltage PWB 8 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update 9 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB