Code: C6610
Description: Fuser pressure release sensor error 1. The fuser pressure release sensor does not turn off even after 3s passed from instructing to reduce the fuser pressure of the fuser pressure release motor or to move the JAM processing position. 2. The fuser pressure release sensor does not turn on even after 6s passed from instructing to add the fuser pressure of the fuser pressure release motor. 3. The lock signal of the fuser pressure release motor became Low for 200ms. (However, when shifting to JAM process, stop the fuser pressure release motor only and not service call turns on in the area from the stop position 500ms before to the stop position.)
Remedy: 1 Reinstalling the fuser unit The foreign objects adhere on the drawer connection terminal of the fuser unit. Or, the drawer connector is not inserted completely. Clean the drawer connection terminal of the fuser unit. Check the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If the pin is normal, reinstall the fuser unit so that the drawer connector is securely connected. Detaching and reattaching the Fuser Unit 2 Checking the connection The connector is not connected properly, or the wire is faulty. Execute U030 [Fuser Release]. If the fuser pressure release motor does not operate properly, reconnect the connectors of the following wires. If there is not continuity, replace the wire. . Fuser pressure release motor - Feed drive PWB . Feed drive PWB - Engine PWB . Drawer connector of the fuser unit - Feed image PWB . Feed image PWB - Engine PWB . Feed image PWB - Feed drive PWB Maintenanc e Mode List Section 8 "PWBs" 3 Replacing the fuser unit The fuser unit is faulty at the fuser pressure release mechanism or the fuser pressure release sensor . Replace the fuser unit. Detaching and reattaching the Fuser Unit 4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update 5 Replacing the feed drive PWB The feed drive PWB is faulty. Replace the feed drive PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB 7 Replacing the feed image PWB The feed image PWB is faulty. Replace the feed image PWB. 8 Replacing the fuser pressure release motor The fuser pressure release motor is faulty. Replace the fuser pressure release motor. 9 Replacing the gear in the fuser pressure releasing system at the main unit The gear of the fuser pressure releasing mechanism at the main unit is faulty. Replace the gears in the fuser pressure releasing mechanism at the main unit.