Code: C6950
Description: IH PWB communication error 1. Communication between the IH PWB and the engine PWB is not established in the initial communication. (150ms interval x 10 times retries are performed) 2. After the initial communication is established, communication between the IH PWB and the engine PWB is not established. (For 500ms)
Remedy: 1 Resetting the main power The power startup delays. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on. 2 Checking the connection The connector is not connected properly. Or, the wire is faulty. (Power supply failure to the IH PWB or communication error by the grounding failure.) Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . Low voltage PWB - IH PWB . IH PWB - Engine PWB Section 8 "PWBs" 3 Checking the power supply voltage The abnormal electric noise is mixed in the power supply voltage. Plug the power cord into another wall outlet.4 Checking the low voltage PWB The fuse on the low voltage PWB is broken. Check the continuity of the fuse (F002) on the low voltage PWB. Then, replace the low voltage PWB if there is no continuity. Detaching and reattaching the Low Voltage PWB 5 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. Detaching and reattaching the IH PWB 6 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update 7 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB