Code: C6980

Description: Fuser unit EEPROM error It is not possible to access the fuser unit EEPROM since it matches one of the following. 1. Five times consecutive detection of no response from the device for more than 5ms on reading / writing. 2. Data read in 2 places does not match 8 consecutive times. 3. Writing data and reading data does not match 8 consecutive times.
Remedy: 1 Checking the fuser unit drawer connectors The fuser unit drawer connectors are not properly connected. If foreign objects adhere on the drawer pins of each drawer connector, clean the drawer pins. If the drawer pins are deformed, repair or replace it. . In case the drawer pins in the fuser unit are faulty and they cannot be repaired by cleaning and fixing: Replace the fuser unit. . In case the drawer pins in the main unit are faulty and they cannot be repaired by cleaning and fixing: Replace the wire. (Part no.: 302ND4637_). If the drawer pins are not faulty, reinstall the fuser unit into the main unit so that the drawer connectors connect each other firmly. Detaching and reattaching the Fuser Unit 2 Replacing the fuser unit The fuser unit is faulty. Replace the fuser unit. Detaching and reattaching the Fuser Unit 3 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB 4 Replacing the feed image PWB The feed image PWB is faulty. Replace the feed image PWB.

← Xem tất cả mã lỗi Kyocera ECOSYS P8060cdn

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie