Mã lỗi C7251 — Kyocera ECOSYS P8060cdn

Code: C7251

Description: Belt thermistor short-circuited The input sampling value of the belt thermistor is at the reference value or less.
Remedy: 1 Reinstalling the primary transfer unit The primary transfer unit is not properly installed. Reinstall the primary transfer unit so that the connector firmly connects. Detaching and reattaching the Primary Transfer Unit 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . Transfer PWB - Transfer connect PWB . Transfer connect PWB - Feed image PWB Section 8 "PWBs" 3 Primary transfer unit replacement The primary transfer unit is faulty. Replace the primary transfer unit. Detaching and reattaching the Primary Transfer Unit 4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update 5 Replacing the transfer connection PWB The transfer connection PWB is faulty. Replace the transfer connection PWB. 6 Replacing the feed image PWB The feed image PWB is faulty. Replace the feed image PWB.