Description: Toner container detection connector error Disconnection of the toner container detection connector was detected when closing the toner container cover.
Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . Container drive unit (RFID PWB) - Feed image PWB Section 8 "PWBs" 2 Checking the container drive unit The connector is not connected properly, or the wire is faulty. If the connector of the wire inside the container drive unit disconnects, reconnect it. If not repaired, replace the container drive unit. 3 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update 4 Replacing the feed image PWB The feed image PWB is faulty. Replace the feed image PWB.