Mã lỗi C8100 — Kyocera ECOSYS P8060cdn

Code: C8100

Description: DF eject release motor error Object: 1000-sheet finisher, 4000-sheet finisher 1. The DF bundle exit sensor does not turn on even 1s passed when the DF exit release motor drives. 2. The DF bundle exit sensor does not turn off even if drives for 1s from on condition.
Remedy: 1 Checking the DF bundle exit unit The eject guide in the DF bundle exit unit is deformed. Repair the DF bundle exit unit. 2 Checking the DF bundle exit unit drive parts The DF bundle exit unit drive parts are not properly attached, or they are faulty. Reattach the DF bundle exit unit drive parts. If not repaired, replace them. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . DF exit release motor - DF PWB . DF bundle exit sensor - DF PWB Section 8 "PWBs" 4 Replacing the DF eject release motor The DF eject release motor is faulty. Execute U240 [Motor] > [Eject Unlock(HP)]. If the DF exit release motor does not operate properly, replace it. Maintenanc e Mode List 5 Checking the DF bundle exit sensor The DF bundle exit sensor is not attached properly or faulty. Reattach the DF bundle exit sensor, then check the sensor operation by executing U241. If the DF bundle exit sensor does not operate properly, replace it. Maintenanc e Mode List 6 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Detaching and reattaching the DF PWB

← Xem tất cả mã lỗi Kyocera ECOSYS P8060cdn

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie