Code: C8160
Description: DF tray motor error (3) Object: 4000-sheet finisher DF tray sensors 4, 5 does not turn on after passing 60s when descending the DF main tray.
Remedy: 1 Checking the DF main tray The DF main tray is not assembled properly. If the DF main tray does not move up and down manually, repair the position where restricts the operation. 2 Checking the DF main tray drive parts The DF main tray drive parts are not properly attached, or they are faulty. Reattach the DF main tray drive parts. If not repaired, replace them. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . DF tray motor - DF PWB . DF tray sensor 4 -DF PWB or, . DF tray sensor 5 (when installing the folding unit) -DF PWB Section 8 "PWBs" 4 Checking the DF tray motor The DF tray motor is faulty. Execute U240 [Motor] > [Tray]. If the DF tray motor does not operate properly, replace it. Maintenanc e Mode List 5 Checking DF tray sensors 4, 5 DF tray sensors 4, 5 are not properly attached, or they are faulty. Reattach DF tray sensor 4 or DF tray sensor 5 (when installing the folding unit), then execute U241 [Finisher] > [Tray L-Limit] or [ Tray L-Limit(BL)]. If DF tray sensor 4 or 5 does not operate properly, replace it. Maintenanc e Mode List 6 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Detaching and reattaching the DF PWB