Code: C8190
Description: DF side registration motor 2 error 1 Object: 1000-sheet finisher, 4000-sheet finisher The home position cannot be detected after passing 3s when relocating to the home position.
Remedy: 1 Checking the rear DF side registration guide The rear DF side registration guide is not assembled properly. If the DF side registration rear guide does not move manually, repair the position where restricts the operation. 2 Checking the rear DF side registration guide drive parts The DF side registration rear guide drive parts are not properly attached, or they are faulty. Reattach the DF side registration rear guide drive parts. If not repaired, replace them. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . DF side registration motor 2 - DF PWB . DF side registration sensor 2 - DF PWB Section 8 "PWBs" 4 Replacing DF side registration motor 2 DF side registration motor 2 is faulty. Execute U240 [Motor] > [Width Test(A3)] or [Width Test(LD)]. If DF side registration motor 2 does not operate properly, replace it. Maintenanc e Mode List 5 Checking DF side registration sensor 2 DF side registration sensor 2 is not properly attached, or it is faulty. Reattach DF side registration sensor 2, then execute U241 [Finisher] > [Width Tail HP]. If DF side registration sensor 2 does not operate properly, replace it. Maintenanc e Mode List 6 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Detaching and reattaching the DF PWB