Description: BF blade motor error Object: 4000-sheet finisher with the folding unit The BF blade sensor does not turn on after passing 3s during the initial operation.
Remedy: 1 Checking the BF blade The BF blade is not assembled properly. If the BF blade does not operation manually, repair the position where restricts the operation. 2 Checking the BF blade drive parts The BF blade drive parts are not properly attached, or they are faulty. Reattach the BF blade drive parts. If not repaired, replace them. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . BF blade motor - BF PWB . BF blade sensor - BF PWB Section 8 "PWBs" 4 Replacing the BF blade motor The BF blade motor is faulty. Execute U240 [Booklet] > [Blade]. If the BF blade motor does not operate properly, replace it. Maintenanc e Mode List 5 Checking the BF blade sensor The BF blade sensor is not properly attached. Reattach the BF blade sensor, then execute U241 [Booklet] > [Blade HP]. If the BF blade sensor does not operate properly, replace it. Maintenanc e Mode List 6 Replacing the BF PWB The BF PWB is faulty. Replace the BF PWB.