Code: C8420
Description: PH slide motor error 2 Object: 4000-sheet finisher or 1000-sheet finisher with the punch unit The paper edge cannot be detected even if shifting 30mm when detecting the paper edge.
Remedy: 1 Checking the punch unit The punch unit is not assembled properly. If the punch slide section does not move front and back manually, repair the position where restricts the operation. 2 Checking the PH drive parts The PH drive parts are not attached properly, or faulty. Reattach the PH drive parts. If not repaired, replace them. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . PH slide motor - PH PWB . PH paper edge sensor 1, 2 - PH PWB . PH PWB - DF PWB Section 8 "PWBs" 4 Replacing the PH slide motor The PH slide motor is faulty. Execute U240 [Motor] > [Punch Move]. If the PH slide motor does not operate properly, replace the DF staple unit. Maintenanc e Mode List 5 Checking the PH paper edge sensors 1, 2 PH paper edge sensors 1, 2 are not properly attached, or they are faulty. Reattach PH paper edge sensor 1 or 2, then check the sensor operation by executing U241. If PH paper edge sensor 1 or 2 does not operate properly, replace it. Maintenanc e Mode List 6 Replacing the PH PWB The PH PWB is faulty. Replace the PH PWB. Detaching and reattaching the PH PWB (PH- 7A/C/D Installation Guide) 7 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Detaching and reattaching the DF PWB