Description: Main program error / Engine - DF communication error (DF) Object: 1000-sheet finisher, 4000-sheet finisher 1. When turning on the power, there was an error in the main program. 2. The communication error between the Engine and DF is detected 10 times continuously. 3. The ready signal is not notified from the DF within 6s after the communication starts.
Remedy: 1 Resetting the main power The program does not start up properly. Turn the power switch and the main power switch off . After 5s passes, turn the main power switch and the power switch on. 2 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. Firmware Update 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. . DF PWB - Engine PWB Section 8 "PWBs" 4 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. Detaching and reattaching the DF PWB 5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Update 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching and reattaching the Engine PWB