Mã lỗi F020 — Kyocera ECOSYS P8060cdn

Code: F020

Description: System memory error (RAM reading/writing error or CPU memory error) The error appears during the reading/writing check of the RAM for the CPU when the main unit starts up.
Remedy: 1 Resetting the main power The communication between the main PWB and the operation panel main PWB is faulty. Turn off the power switch and the main power switch. After 5 seconds, turn on the main power switch and the power switch. 2 Executing U021 The backup RAM data is faulty. Execute U021 to initialize the backup RAM data. Maintenanc e Mode List 3 Checking the main PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB. Section 8 "PWBs" Detaching and reattaching the Main PWB