Mã lỗi F021 — Kyocera ECOSYS P8060cdn

Code: F021

Description: System memory error (RAM reading/writing error or ASIC memory error) Error occurred when checking read/write of RAM for main PWB ASIC at start up.
Remedy: 1 Resetting the main power The main PWB does not properly start up. Turn off the power switch and the main power switch. After 5 seconds, turn on the main power switch and the power switch. 2 Executing U021 The backup RAM data is faulty. Execute U021 to initialize the backup RAM data. Maintenanc e Mode List 3 Checking the main PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB. Section 8 "PWBs" Detaching and reattaching the Main PWB