Code: F000
Description: Communication Error between Main PCB and Panel PCB
Communication failure during the start-up or operation. * : Only 3 in 1 25/26 ppm model, 4 in 1 20/21, 25/26 ppm model
Communication failure during the start-up or operation. * : Only 3 in 1 25/26 ppm model, 4 in 1 20/21, 25/26 ppm model
Causes: Defective main PWB. Defective operation PWB.
Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB .
Defective operation PWB. Replace the operation PWB and check for correct operation.
Defective operation PWB. Replace the operation PWB and check for correct operation.