Code: 6020
Description: Abnormally high fuser thermistor temperature
Fuser thermistor detects a temperature higher than 210°C/410°F for 3 s
Fuser thermistor detects a temperature higher than 210°C/410°F for 3 s
Causes: Deformed connector pin. Shorted fuser thermistor. Defective power source PWB. Defective main PWB.
Remedy: Deformed connector pin. If the I/F connector pins of the fuser unit and the main unit are deformed owing to foreign matters, such as paper dusts, replace the connectors or the units including the connectors.
Shorted fuser thermistor. Replace the fuser unit .
Defective power source PWB. Replace the power source PWB
Defective main PWB. Replace the main PWB and check for correct operation .
Shorted fuser thermistor. Replace the fuser unit .
Defective power source PWB. Replace the power source PWB
Defective main PWB. Replace the main PWB and check for correct operation .