Code: 2000
Description: Main motor error The main motor ready input is not given for 2 s during the main motor is ON.
Remedy: Defective harness between main motor (CN1) and control PWB (YC17), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective main motor. Replace the main motor.
Defective control PWB. Replace the control PWB.
Defective drive transmission system of the main motor. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective main motor. Replace the main motor.
Defective control PWB. Replace the control PWB.