Code: 6030
Description: Broken fuser thermistor wire
Average input AD given by the thermistor is less than 2 for 300msec.
Average input AD given by the thermistor is less than 2 for 300msec.
Causes: Defective connector cable or poor contact in the connector. Broken fuser thermistor wire. Fuser thermostat triggered. Defective main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser unit and main PWB (YC15)
Broken fuser thermistor wire. Replace the fuser unit .
Fuser thermostat triggered. Replace the fuser unit .
Defective main PWB. Replace the main PWB and check for correct operation .