Code: C1
Description: Option duplexer DU-60 communication error
Communication error between engine board and option duplexer DU-60.
Communication error between engine board and option duplexer DU-60.
Causes: • Defective gate array U204 on the engine board (KP-864). • Blown-out fuse (F202) on the engine board. • Improper installation between printer and option duplexers. • Defective harness (S02400) between engine board and option unit interface connector. • Improper connector insertion. • Defective option duplexer DU-60. PF-60.