Code: C0870
Description: Fax control PWB to main PWB highcapacity data transfer problem
• High-capacity data transfer between the optional fax control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times.
• High-capacity data transfer between the optional fax control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times.
Causes: Poor contact in the connector terminals. Defective fax control PWB or main PWB.
Remedy: Check the connection of connector YC1 on the fax control PWB and YC1 on the main PWB, and the continuity across the connector terminals. Repair or replace if necessary. Replace the fax control PWB or main PWB and check for correct operation.