Code: 6020
Description: Abnormal high temperature error
HTEMP* remains high for longer than 4 seconds since the heater lamp is on. The heater lamp continues to be turn on for longer than 60 seconds.
HTEMP* remains high for longer than 4 seconds since the heater lamp is on. The heater lamp continues to be turn on for longer than 60 seconds.
Causes: Defective CPU U1 or comparator U9 on the engine board. Defective engine board (KP-1081). Defective thermistor. Defective photo coupler on the power supply unit for the heater lamp.