Code: 4200
Description: Laser output (pin photo sensor) error
The pin photo signal (PDN) is not output within a specified time after the polygon motor ready signal (POLRDYN) becomes ready (L level).
The pin photo signal (PDN) is not output within a specified time after the polygon motor ready signal (POLRDYN) becomes ready (L level).
Causes: Defective harness between PD PWB (YC1) and main PWB (YC16), or improper connector insertion. Defective APC PWB. Defective PD PWB. Defective main PWB.
Remedy: Defective harness between PD PWB (YC1) and main PWB (YC16), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective APC PWB. Replace the laser scanner unit.
Defective PD PWB. Replace the laser scanner unit.
Defective main PWB. Replace the main PWB.
Defective APC PWB. Replace the laser scanner unit.
Defective PD PWB. Replace the laser scanner unit.
Defective main PWB. Replace the main PWB.