Code: 4000
Description: Polygon motor synchronization error
The polygon motor ready input is not given for 10 s during the polygon motor is ON.
The polygon motor ready input is not given for 10 s during the polygon motor is ON.
Causes: Defective connector cable or poor contact in the connector. Defective polygon motor. Defective main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Laser scanner unit and main PWB (YC14)
Defective polygon motor. Replace the laser scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.
Defective polygon motor. Replace the laser scanner unit.
Defective main PWB. Replace the main PWB and check for correct operation.