Code: 6130
Description: Broken fuser thermistor 1 wire
Input from fuser thermistor 1 is less than 1 (A/D value) for more than 1 s.
Input from fuser thermistor 1 is less than 1 (A/D value) for more than 1 s.
Causes: Poor contact in the fuser thermistor 1 connector terminals. Broken fuser thermistor 1 wire. Fuser thermistor 1 installed incorrectly.
Remedy: Poor contact in the fuser thermistor 1 connector terminals. Reinsert the connector.
Broken fuser thermistor 1 wire. Measure the resistance. If it is ∞, replace the fuser thermistor 1.
Fuser thermistor 1 installed incorrectly. Check and reinstall if necessary.
Broken fuser thermistor 1 wire. Measure the resistance. If it is ∞, replace the fuser thermistor 1.
Fuser thermistor 1 installed incorrectly. Check and reinstall if necessary.