Code: C26
Description: Scanning system
Peak detection error: Lighting of the exposure lamp (white reference) is not detected when power is turned ON.
Peak detection error: Lighting of the exposure lamp (white reference) is not detected when power is turned ON.
Remedy: Does the exposure lamp light? (Perform the output check in the test mode: 04-267)
YES Replace the CIS unit.
NO 1) Check if the connector of the CIS unit are disconnected. 2) Check the MAIN board if the connector (CN6) is disconnected and the harness is short circuited or open circuited. 3) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 4) Replace the MAIN board. 5) Replace the CIS unit.
YES Replace the CIS unit.
NO 1) Check if the connector of the CIS unit are disconnected. 2) Check the MAIN board if the connector (CN6) is disconnected and the harness is short circuited or open circuited. 3) Check if the conductor pattern on the MAIN board is short circuited or open circuited. 4) Replace the MAIN board. 5) Replace the CIS unit.